Healthcare professional at the patient bedside in front of the PrisMax System

CRRT Filtersets


Vantive CRRT filtersets maximise simplicity and efficiency

Each CRRT filterset can be used with all CRRT modalities and with any anticoagulant protocol, so there is no need to list multiple types on the order set or to keep several types in inventory. CRRT modalities can be changed during therapy without changing the set.


CRRT filterset features

Suitable for all CRRT prescriptions

Each CRRT filterset works with all CRRT modalities and any anticoagulant protocol, providing flexibility to meet patient needs and create operational efficiencies.

Unique clearance mechanism

Vantive’s AN69ST membrane has a unique mechanism of action that adsorbsthe higher-molecular-weight toxins that can be present in patients with AKI.

Exclusively for PrisMax and Prismaflex systems

Engineered to work with the PrisMax and Prismaflex systems, Vantive’s CRRT filtersets are bar-coded for set recognition, with step-by-step setup guidance supporting reduced downtime and lasting therapy proficiency.2


Simplify therapy set-up and management

Vantive CRRT filters are permanently pre-connected to colour-coded tubing lines for easy setup and accurate connection between lines and bags.Each set is a closed system, minimising setup steps and reducing the potential for touch contamination.3
 
The pre-connected filtersets have a specifically designed deaeration chamber to help remove air without user intervention, eliminate the blood and air interface, and reduce blood clot formation.2


Optimise operational efficiencies in the ICU

Vantive CRRT filtersets help reduce inventory requirements and optimise operational efficiencies because each set can work with all CRRT modalities and any anticoagulant protocol, as noted in the table below.4 Each filterset is bar-coded for set recognition on the PrisMax and Prismaflex systems, with setup guidance to support reduced therapy downtime and offer lasting therapy proficiency.2

A healthcare professional stands with arms crossed looking into the distance, in front of the PrisMax System

Meet clinical needs across CRRT modalities

 

Membrane

Minimal patient size

SCUF

CVVH

CVVHD

CVVHDF

Heparin

No anti-coagulant

HF20PAES8 kg  ✓  ✓  ✓  ✓  ✓  ✓

ST60

AN69ST

11 kg

  ✓  ✓  ✓   ✓   ✓    ✓

ST100

AN69ST

30 kg

  ✓  ✓  ✓   ✓   ✓   ✓

ST150

AN69ST

30 kg

  ✓  ✓ ✓   ✓   ✓   ✓

Membrane options to fit individual patient needs

Vantive’s CRRT filtersets include options for adult patients and for low-body-weight patients, all with lower extracorporeal blood volumes. 

Vantive CRRT filtersets feature the unique AN69ST membrane for exceptional biocompatibility and a unique adsorptive capability to clear the higher-molecular-weight toxins that may be present in patients with AKI.1


AN69ST membrane for AKI attracts large molecules

Since patients with AKI can have higher-molecular-weight toxins present in their blood, the AN69ST membrane has a unique mechanism of action that adsorbs1 higher molecular weight toxins such as myoglobin, and beta 2 microglobulin, in addition to the smaller uremic toxins removed by industry-standard polysulfone-based filter membranes.

The distribution of sulfonate groups throughout the membrane structure allows adsorption to occur on the surface and across the whole membrane, which results in stable membrane performance over time.1

AN69_membrane_vs_PAES_membrane

A variety of AN69ST filtersets to meet prescription targets

The AN69ST membrane is available in three different sizes to help meet individual patient needs.

 ST60 setST100 setST150 set
Membrane effective surface area0.6 m21 m21.5 m2
Blood volume in set97 mL155 mL193 mL
Minimal patient weight11 kg30 kg30 kg

Related products

Contact Us

Connect with Vantive to learn more about our CRRT filtersets.

Vantive, AN69, Prismaflex and PrisMax and are trademarks of Vantive Health LLC or its affiliates.

References
  1. Thomas M, Moriyama K, Ledebo I. AN69ST: Evolution of the world's first high permeability membrane. Contrib Nephrol. 2011;173:119-129.

  2. Vantive Health LLC. PrisMax Operator’s Manual AW8061. May, 2022.

  3. Vantive Health LLC. ST60/ST100/ST150 sets with AN69 Spec Sheet. 1000015673. August, 2024. Internal Documentation.

  4. Vantive Health LLC. FMC Product Range Acute Therapies, 2014. Internal Documentation.